When you turn the thermostat up and nothing happens, the fault could be anywhere from a dead thermostat battery to a failed control board. We connect you with a local heating company in Star Prairie, WI that can track it down, but there are a few checks worth doing first.
Start with the simple stuff
- Thermostat on Heat, set a few degrees above the room, and the display is on
- Furnace service switch on (a light switch on the wall or the side of the furnace)
- Breaker in the panel not tripped
- Blower door seated; a push switch behind it kills power when the door is loose
- Gas valve handle on the supply pipe turned in line with the pipe
- Filter not clogged, which can trip the furnace on its high limit
- On condensing furnaces, the outside PVC pipes clear of snow and ice
Read the light
Most furnaces have a small window in the blower door where you can see an LED on the control board. A steady glow usually means power and no fault. A blinking pattern is a code; count the flashes and match it to the chart printed inside the panel. No light at all points to no power reaching the board: the switch, breaker, door switch, a blown low-voltage fuse on the board or a failed transformer.
Thermostat problems
A blank thermostat screen often means dead batteries or a lost 24-volt supply. Smart thermostats can lose power if the C wire isn't connected properly. If the thermostat looks fine but the furnace doesn't respond, the tech can jump the thermostat terminals at the board to tell whether the issue is the thermostat or the furnace. See thermostat repair for more.
What the tech checks
The diagnosis follows the power: 120 volts in, the door switch, the transformer's 24-volt output, the board fuse, the thermostat call, and then each step of the start-up sequence. If the furnace starts but quits before lighting, the trouble is usually the pressure switch, igniter or flame sensor instead.
What drives the cost
A blown board fuse or tripped door switch is a short visit. A transformer is moderate. A control board is a larger part and varies a lot by brand. After-hours timing raises the service fee.
Don't keep resetting it
Flipping the power off and on can clear a lockout, and once is fine. If it locks out again, something is causing it. Repeated resets can mask a real safety problem. If the furnace has power and runs but only blows cool air, check furnace blowing cold air instead.